Morgan Home Inspections (sample company)
(555) 010-0100 · office@example.com
Home Inspection Report
456 Harbor View Drive · Sample Property

- Client
- Jordan Taylor (fictional client)
- Client email
- jordan@example.com
- Date
- October 15, 2026 at 2:00 PM
- Inspection type
- Pre-Purchase
- Inspector
- Alex Morgan (sample inspector)
- License #
- HI-00000 (sample)
- Year built
- 1986
- Square feet
- 1,840
- Occupancy
- Vacant
- Selected services
- Pool Inspection · Mold Inspection / Testing · Radon Testing · WDO Report · Four-Point Inspection · Wind Mitigation Report
- Buyer's Agent
- Casey Rivera (fictional agent) · casey@example.com · (555) 010-0142
- Listing Agent
- Morgan Lee (fictional agent) · morgan@example.com · (555) 010-0177
Main Inspection Summary
This combined sample shows a full home inspection with linked services. The pool gate does not self-close (safety concern), the mold assessment found a leak-related moisture issue under the hall bath sink, and the third-party WDO provider reported mud tubes at the rear sill plate. Radon results are still awaiting the laboratory and are not included in this version; an updated report will be sent once results are reviewed.
Contents
- Main Inspection Summary
- Summary of concerns
- Full Home Inspection
- 1. Roof
- 2. Exterior
- 3. Lots and Grounds
- 4. Structure/Foundation
- 5. Attic
- 6. Electric
- 7. Plumbing
- 8. HVAC
- 9. Living Space
- 10. Kitchen
- 11. Master Bathroom
- 12. Bathroom 1
- 13. Bathroom 2
- Pool Inspection · Completed
- Mold Inspection / Testing · Completed
- WDO Inspection · Completed
- Radon Testing · Awaiting Third-Party Report
- Items not inspected & notes
- Scope and Limitations of the Home Inspection
- Inspection Details
- Supporting documents
Summary of concerns
This summary is not a substitute for reading the full report.
2
- Kitchen receptacle lacks GFCI protection — Electric → GFCI Protection
Have a licensed electrician evaluate and provide appropriate GFCI protection before use.
- Pool gate does not self-close — Pool Inspection → Barriers, Gates & Alarms → Gate Operation
Have the gate hinges and latch adjusted or replaced so the gate self-closes and self-latches.
11
- Leak at sink drain connection — Plumbing → Drains
Have a qualified plumber repair the leaking connection, then check the cabinet for moisture damage and verify the repair under flow.
- Raised deck slab edge — Pool Inspection → Deck & Surrounding Areas → Trip Hazards
Have the deck section leveled or ground to remove the trip edge.
- Drip at filter union — Pool Inspection → Visible Plumbing & Valves → Leakage
Have a pool technician reseal or replace the union.
- Staining and growth-like substance below hall bath sink — Mold Inspection / Testing → Interior Observations → Staining
Have a plumber repair the leak source, then have affected materials cleaned or replaced by a qualified remediation contractor.
- Mud tubes at basement sill plate — WDO Inspection → Evidence of Wood-Destroying Organisms → Evidence Type
Have a licensed pest control provider evaluate and treat, and have damaged wood evaluated by a qualified contractor.
- Grading — Lots and Grounds
Improve grading along the rear wall to direct surface water away from the foundation.
- Exhaust Fan — Master Bathroom
Exhaust fan did not operate when switched on.
- Location — Mold Inspection / Testing → Moisture Measurements
Example reading: 28.7% on a pin-type meter at the cabinet back wall (elevated relative to 11% at a dry reference wall).
- Further Evaluation — Mold Inspection / Testing → Findings & Recommendations
Locate and repair the moisture source before cleaning affected materials.
- Affected Components — WDO Inspection → Visible Damage
Limited surface damage at about two feet of the rear sill plate (sample observation).
- Further Evaluation — WDO Inspection → Recommendations & Limitations
Treatment and repair decisions should follow the provider's recommendations. Concealed areas may contain additional damage.
7
- Debris in rear gutter — Roof → Gutters & Drainage
Clean gutters and downspouts and confirm water discharges away from the foundation.
- Filters — HVAC
Replace the dirty air filter with the manufacturer-recommended size and type.
- Shower/Tub Enclosure — Master Bathroom
Caulk at the shower pan corner is cracked; re-seal to prevent water intrusion.
- Sinks & Faucets — Bathroom 2
Slow drain at the sink; clear the trap.
- Filter — Pool Inspection → Circulation & Filtration
Filter pressure gauge read high; cleaning is likely due.
- Original Results — Mold Inspection / Testing → Laboratory Results
Example laboratory results attached. Indoor air sample was lower than the outdoor control; the cabinet tape lift showed growth-like particles.
- Wood-to-Soil Contact — WDO Inspection → Conducive Conditions
Rear deck post bears directly on soil.
1. Roof
Gutters & Drainage
Leaves and debris were observed in the rear gutter.
Debris in rear gutter
Location: Rear eave
Accumulated leaves may restrict drainage.
Recommendation: Clean gutters and downspouts and confirm water discharges away from the foundation.
Refer to: Gutter maintenance professional

2. Exterior
Siding
Accessible siding was intact at the time of inspection.
3. Lots and Grounds
Grading
Improve grading along the rear wall to direct surface water away from the foundation.
4. Structure/Foundation
Foundation
No significant displacement observed in accessible foundation walls.
5. Attic
Roof Sheathing
Not inspected because: Stored belongings blocked safe access to the attic hatch.
6. Electric
GFCI Protection
Kitchen receptacle lacks GFCI protection
Location: Kitchen counter beside sink
The kitchen receptacle near the sink did not demonstrate ground-fault protection when tested.
Recommendation: Have a licensed electrician evaluate and provide appropriate GFCI protection before use.
Refer to: Licensed electrician
7. Plumbing
Drains
Leak at sink drain connection
Location: Kitchen sink cabinet
Water droplets were observed at the drain connection during fixture operation, with moisture staining on the cabinet base.
Recommendation: Have a qualified plumber repair the leaking connection, then check the cabinet for moisture damage and verify the repair under flow.
Refer to: Qualified plumber

8. HVAC
Filters
Replace the dirty air filter with the manufacturer-recommended size and type.
9. Living Space
Walls & Ceilings
Accessible wall and ceiling finishes appeared serviceable.
10. Kitchen
Garbage Disposal
No garbage disposal is installed.
11. Master Bathroom
Cabinets & Vanity
Vanity doors and drawers operated normally.
Shower/Tub Enclosure
Caulk at the shower pan corner is cracked; re-seal to prevent water intrusion.
Receptacles & GFCI
Receptacle near the sink tripped and reset at GFCI.
Exhaust Fan
Exhaust fan did not operate when switched on.
12. Bathroom 1
Toilet
Toilet flushed and refilled normally; base was secure.
Bathtub
Tub filled and drained normally.
13. Bathroom 2
Sinks & Faucets
Slow drain at the sink; clear the trap.
Additional report
Pool Inspection
Completed
Assigned inspector: Alex Morgan (sample inspector)
The pool, deck, barrier, visible plumbing, and operating equipment were evaluated from accessible areas.
Service limitations
Underground piping, the shell beneath water, and concealed bonding were not evaluated.
Pool Inspection
1. Pool & Spa Information
Pool Type
Not rated- Pool Type
- In-ground
Spa Presence
Not rated- Spa present
- No
Equipment Location
Not rated- Pool/Spa Equipment Location
- Along the right side of the home behind the fence.
Inspection Conditions
Not rated- Weather at Time of Inspection
- Clear/Sunny
- Temperature
- 84 °F
Pool Inspection
2. Pool Surfaces & Structure
Interior Pool Surface Material
Not rated- Interior Pool Surface Material
- Plaster/Marcite
Light staining and minor plaster roughness at the steps.
Coping
Accessible coping stones were secure at the time of inspection.
Pool Inspection
3. Deck & Surrounding Areas
Trip Hazards
Raised deck slab edge
Location: Deck near equipment pad
An offset of roughly one inch was observed between two deck slabs.
Recommendation: Have the deck section leveled or ground to remove the trip edge.
Refer to: Concrete contractor
Pool Inspection
4. Barriers, Gates & Alarms
Gate Operation
Pool gate does not self-close
Location: Side yard pool gate
The pool gate remained open when released from a partly open position.
Recommendation: Have the gate hinges and latch adjusted or replaced so the gate self-closes and self-latches.
Refer to: Fence or pool safety contractor
Fencing
Perimeter fence was continuous where visible.
Pool Inspection
5. Circulation & Filtration
Pool Pump
Pump operated during the inspection; no unusual noise noted.
Filter
Filter pressure gauge read high; cleaning is likely due.
Pool Inspection
6. Visible Plumbing & Valves
Leakage
Drip at filter union
Location: Equipment pad
Water was dripping from the union below the filter while the pump ran.
Recommendation: Have a pool technician reseal or replace the union.
Refer to: Pool service technician

Pool Inspection
7. Electrical Observations
GFCI Testing
Pool light circuit tripped and reset at the GFCI device.
Pool Inspection
8. Heating & Spa Equipment
Heater
Not inspected because: Heater was shut off at the gas supply and was not operated.
Pool Inspection
9. Safety Components
Visible Drain Covers
Visible main drain cover was in place; date stamp not legible from deck.
Pool Inspection
10. Limitations & Recommendations
Inaccessible Areas
Not ratedUnderground piping, pool shell beneath water, and concealed bonding were not evaluated.
Additional report
Mold Inspection / Testing
Completed
Assigned inspector: Alex Morgan (sample inspector)
Visual moisture assessment with limited sampling at client-selected locations.
Service limitations
Sampling is a snapshot of conditions at the time of collection. Laboratory results shown are fictional examples.
Mold Inspection / Testing
1. Inspection Information
Areas Included
Hall bathroom, bedroom 2, and HVAC closet at the client's request.
Mold Inspection / Testing
2. Interior Observations
Staining
Staining and growth-like substance below hall bath sink
Location: Hall bathroom sink cabinet
Water staining and a dark growth-like substance were observed on the cabinet back wall with elevated moisture readings.
Recommendation: Have a plumber repair the leak source, then have affected materials cleaned or replaced by a qualified remediation contractor.
Refer to: Plumber; remediation contractor

Mold Inspection / Testing
3. Moisture Measurements
Location
Example reading: 28.7% on a pin-type meter at the cabinet back wall (elevated relative to 11% at a dry reference wall).
Mold Inspection / Testing
4. Sampling Details
Sample Location
M-01 tape lift (hall bath cabinet), M-02 air (bedroom 2), M-03 air (outdoor control). Collected Oct 15, 2026 (sample dates).
Mold Inspection / Testing
5. Laboratory Results
Original Results
Example laboratory results attached. Indoor air sample was lower than the outdoor control; the cabinet tape lift showed growth-like particles.
Mold Inspection / Testing
6. Findings & Recommendations
Further Evaluation
Locate and repair the moisture source before cleaning affected materials.
Mold Inspection / Testing
7. Limitations & Attachments
Concealed Areas
Wall cavities and areas behind fixed cabinets were not opened. Sampling reflects conditions at the time of collection only.
Additional report
WDO Report
Completed
Third-party provider: Riley Chen (fictional)
Example Pest Services LLC (fictional) · (555) 010-0199 · pest@example.com · License / certification: SAMPLE-0000 (not a real license)
Visual inspection of accessible areas for evidence of wood-destroying organisms.
Service limitations
Concealed areas behind finishes, insulation, and stored items were not visible.
WDO Inspection
1. Inspection & Provider Information
Provider
Performed by a third-party provider (fictional): Example Pest Services LLC.
WDO Inspection
2. Structure & Accessible Areas
Areas Inspected
Exterior perimeter, basement, garage, and accessible attic framing.
WDO Inspection
3. Evidence of Wood-Destroying Organisms
Evidence Type
Mud tubes at basement sill plate
Location: Rear basement wall
Earthen tubes consistent with subterranean termite activity were observed on the foundation wall leading to the sill plate.
Recommendation: Have a licensed pest control provider evaluate and treat, and have damaged wood evaluated by a qualified contractor.
Refer to: Licensed pest control provider

WDO Inspection
4. Visible Damage
Affected Components
Limited surface damage at about two feet of the rear sill plate (sample observation).
WDO Inspection
5. Conducive Conditions
Wood-to-Soil Contact
Rear deck post bears directly on soil.
WDO Inspection
6. Recommendations & Limitations
Further Evaluation
Treatment and repair decisions should follow the provider's recommendations. Concealed areas may contain additional damage.
WDO Inspection
7. Original Provider Report
Completed Third-Party Report
Sample provider document attached — generic example, not an official or regulatory form.
Radon Testing
Awaiting Third-Party Report
Assigned inspector: Alex Morgan (sample inspector)
Results pending — findings and results for this service are not included in the current report.
Scope & limitations
This abbreviated sample shows selected items across the inspection categories. It is not a completed inspection or a report on an actual property. Roof observed from ground level; concealed areas were not evaluated.
Items not inspected
- Attic → Roof Sheathing: Stored belongings blocked safe access to the attic hatch.
- Pool Inspection → Heating & Spa Equipment → Heater: Heater was shut off at the gas supply and was not operated.
Morgan Home Inspections (sample company)
Scope and Limitations of the Home Inspection
- Property
- 456 Harbor View Drive · Sample Property
- Inspection date
- October 15, 2026
- Inspector
- Alex Morgan (sample inspector) · License #HI-00000 (sample)
- Report ID
- SAMPLE
This home inspection is a visual, noninvasive examination of the readily accessible systems and components of the property that were present and observable at the time of the inspection. The inspection is intended to identify and document material defects, safety concerns, signs of deterioration, and components that may require repair, maintenance, monitoring, or additional evaluation.
The inspection may include visible and accessible portions of the roof, exterior, site and grounds, structure, foundation, crawlspace, attic, insulation and ventilation, electrical system, plumbing system, heating and cooling systems, interior rooms, doors, windows, installed kitchen appliances, bathrooms, garage, and other components included within the inspection agreement.
The inspection and report represent the condition of the property only at the time of the inspection. Conditions can change after the inspection because of weather, occupancy, repairs, system operation, component failure, or other circumstances.
General Limitations
The inspection is limited to areas and components that are visible, safely accessible, and included within the agreed inspection scope. The inspector does not dismantle systems, remove permanently installed finishes, move heavy furniture, disturb insulation, lift flooring, open walls, excavate soil, or perform destructive testing.
Areas may be limited or excluded when access is restricted by personal belongings, locked doors, stored materials, vegetation, unsafe conditions, insufficient clearance, weather, animals, active construction, disconnected utilities, or other conditions beyond the inspector’s control. These limitations will be documented in the report when applicable.
The inspection is not technically exhaustive and does not determine every possible defect. Concealed, intermittent, latent, cosmetic, or future conditions may not be visible or discoverable during a limited visual inspection.
The inspection is not a guarantee, warranty, insurance policy, appraisal, engineering analysis, environmental assessment, code-compliance inspection, or certification that the property is free from defects. The report does not predict the remaining service life of any component or guarantee its continued operation.
System Operation
Systems and components are operated using normal homeowner controls when utilities are available and operation is safe. The inspector is not required to activate shutoff valves, light pilot flames, reset breakers, operate emergency controls, or test equipment that is disconnected, shut down, inaccessible, unsafe, or may be damaged through normal operation.
Specialized and Environmental Conditions
Unless specifically included in the inspection agreement, the inspection does not include testing or evaluation for mold, radon, asbestos, lead-based paint, formaldehyde, indoor air quality, soil contamination, underground storage tanks, water quality, wood-destroying organisms, pests, septic systems, wells, security systems, low-voltage systems, generators, solar systems, or other specialized environmental or technical conditions.
Separate testing or evaluation by an appropriately qualified professional may be recommended when evidence of a possible concern is observed.
Repairs and Further Evaluation
When the report recommends repair, correction, servicing, or further evaluation, the work should be completed by an appropriately qualified professional. Recommended repairs should be evaluated and completed before the end of the applicable inspection or contingency period whenever possible.
Repair costs are not included unless specifically stated. Any cost information provided is an estimate only and should be confirmed through qualified contractors.
Report Use
The inspection report must be read in its entirety, including the summary, photographs, comments, limitations, and recommendations. The summary is provided for convenience and is not a substitute for reviewing the complete report.
The inspection report is prepared exclusively for the client named in the inspection agreement. Other parties should not rely on the report without written authorization from the inspector or inspection company.
The inspection agreement, applicable standards of practice, and state requirements control the scope of the inspection. If a conflict exists between this report section and the signed inspection agreement, the signed inspection agreement will govern.
Sample Report — fictional inspection company, property, client, inspector, and findings, prepared with SuperiorInspect. Photos are illustrative, AI-generated examples, not customer inspection media.
Prepared by Alex Morgan (sample inspector), License #HI-00000 (sample) · Morgan Home Inspections (sample company)
Inspection Details
Weather at Time of Inspection
- Weather Conditions
- Partly Cloudy
- Temperature
- 68°F
Present at Inspection
- Buyer — Jordan Taylor (fictional)
- Buyer's Agent — Casey Rivera (fictional)
Supporting documents and third-party attachments
Mold Inspection / Testing
Sample laboratory results (example, not authentic).pdfClearly labeled example laboratory document.
Original document: /samples/sample-mold-lab-results.pdf
WDO Report · Third-party document
Sample WDO provider document (generic example).pdfGeneric sample provider document — not an official or regulatory form.
Original document: /samples/sample-wdo-provider-report.pdf